Surgical gowns Unreinforced gowns
Test Method Units Goal Convertors® Trimax 39515 Convertors® Optima 9545 Medline DYNJP2002 J&J 0551
Basis Weight ASTM D3776 oz/yd2 N/A 1.9 2.3 2.3 2.3
Water Impact AATCC 42 g L 0.06 0.12 0.21 0.13
Hydrostatic Pressure AATCC 127 cm H 50.8 30.1 24.5 30.8
Mechanical Pressure ASTM F1819 psi H 2.9 1.1 0.6 1.0

Basis Weight

Determines the weight of the structure.

Hydrostatic Pressure

Measures the resistance of fabrics to the penetration of water under constantly increasing hydrostatic pressure. Indicates how the material will perform under external pressure of fluids accumulating on fabric.

Water Impact

Measures the resistance of fabrics to the penetration of water by spray impact. Indicates how the material will perform when fluids fall or splash onto the fabric.

Mechanical Pressure

Measures the resistance of materials used in protective clothing to synthetic blood under the conditions of liquid contact and increasing direct mechanical pressure. Simulates the condition of leaning on the fabric surface.

Data taken from Requests 030497, 020897, 050599, 130100, 040301, 070901, 030201

Surgical Drapes Laporatomy Drape Turban Drape
Test Method Units Goal Convertors® 29410 Medline DYNJP1005 J&J 1246 Medline
Basis Weight ASTM D3776 oz/yd2 N/A 2.0 NT 2.2 2.2
Hydrostatic Pressure AATCC 127 cm H 29.0 NT 24.6 24.2
Alcohol Repellency IST 80.6 rating H 9.9 NT 9 10
Mason Jar IST 80.5 min H 60+ NT 60+ 60+
Water Impact AATCC 42 g L 0.734 NT 3.119 0.832
Gelbo Flex Linting IST 160.1 # particles 1.0 um/ft3/min L 2326 344 441 NT
Mechanical Pressure ASTM F1819 psi H 0.82 0.8 0.8 NT

NT = Not Tested / ND = No Data
Data taken from Request 020100, 030201, 130100, 040301, 210101